TAS-986 Atomic Absorption Spectrometer (Flame & Furnace)
$24,800

The TAS-986 is one of the highest-grade fully automatic atomic absorption spectrometers. All operations are controlled through the PC, with the AA-Win software based on a WINDOWS platform. The design with the flame burner and graphite furnace in one compact unit enables automatic interchanging of two analytical methods.

There are two background correction methods, self-reversal background correction and deuterium lamp background correction, to ensure the most precise analytical results. A self- aligning eight-lamp turret makes for user-friendly multi-elemental atomic measurements. The unique furnace heating design ensures uniform heating and guarantees measurement accuracy. All around automatic safety precautions ensure reliable operations. ONE (1) YEAR WARRANTY included.

Please allow up to four (4) weeks for delivery.

GenTech Certified: 1-Year Warranty on Used Lab Equipmentrequest quote on used laboratory equipment

Specifications | Features | Back to New Spectrophotometers


Add $690 for new computer and monitor

Specifications
Optical System: Czerny-Turner(C-T) Type Monochromator
Wavelength Range: 190nm ~ 900nm
Spectral Bandwidth: 0.1 nm, 0.2 nm, 0.5nm, 1.0 nm, and 2.0 nm. (5 steps, with automatic changeover)
Wavelength Accuracy: +/-0.3 nm (automatic correction)
Wavelength Reproducibility: 0.2 nm
Resolution: over 0.3 nm
Baseline Stability: 0.005A/30 min
Flame Analysis
Sensitivity: Cu 5µg/ml > 0.850 Abs
Burner Head: Titanium Alloy Burner
Nebulizer: High-efficiency Glass Nebulizer
Atomization Chamber: Corrosion-resistant Material
Position Adjustment: Automatic flame and furnace changeover, Automatic flame burner optimum height setting
Safety: Automatic ignition of mixing air-acetylene gas with protection control
Graphite Furnace Analysis
Characteristic Mass (Cd): 0.8Pg
Temperature Range: Ambient - 2650°C
Heating: voltage feedback control when drying and ashing, optical temperature control when atomizing
Heating Program: up to 9 steps with choices of ramp, ladder and full-power heating
Background Correction
Deuterium Lamp Background Correction: 1.0 Abs
Self-Reversal Background Correction: 3.0 Abs
Data Processing
Analytical Method: flame AA, graphite furnace, hydride, and flame emission
Determination Method: calibration curves (1~3 order), standard addition method
Repetition Times: 1~20 times with calculations of average value, SD and RSD
Result Printout: output of parameters, data, spectra and calibration curves
Mainframe
Light Source: 8 lamps, 2 lamps simultaneously lit (with one preheat)
Power Supply: 220V/50Hz three-phase AC, 200W(mainframe), 5000W(graphite furnace)
Mainframe Size: 110cm x 50cm x 45cm, 75kg
Package: Part 1: 1340x760x570mm 158Kg; Part 2: 540x410x750mm 42Kg; Part 3: 760x760x700mm 75Kg
Graphite Furnace Power Supply System 50cm x 50cm x 45cm, 50kg
Features: Fully Automatic Control
  • The integration of flame burner and graphite furnace in one compact unit enables automatic interchanging between the flame mode and furnace mode using few simple keystrokes.
  • Eight-Lamp turret for automatic positioning of each hollow cathode lamp.
  • Automatic fuel gas(C2H2) flow rate adjustment to optimize combustion efficiency in element analysis.
  • Automatic adjustment of burner height for optimized analysis conditions.
  • Automatic Reflecting/Transmitting beamsplitter positioning (to lead the light of deuterium lamp into optical path) when the Deuterium Lamp Background Correction function is selected.
  • Automated wavelength scanning and peak-seeking
  • Automatic switchover of spectral bandwidth (5 choices).
  • Automatic negative voltage and lamp current adjustment, automatic AA and BG energy balance, automatic igniting and interlock protection in case of flameout.
Safety Assurance
  • Flame Monitoring: Constant monitoring. When accidental flameout occurs, an alarm is given and the acetylene flow is stopped immediately
  • Pressure Monitoring: Constant air pressure detection. When abnormalities are detected, acetylene flow will be automatically cut off for safety fire extinguishing. The argon gas pressure monitor will disconnect the electricity to the graphite tube when an absence of the protective argon gas is detected.
  • Cooling water flow monitoring: The power supply to the furnace will only be activated for heating when the cooling water flow is determined enough to cool down the furnace body.
  • Graphite Tube Fracture Protection: Power supply used for heating is automatically shut off and an alarm is given if a sudden graphite tube fracture is detected.
TAS-986 Atomic Absorption Spectrometer (Flame & Furnace)
Terms & Conditions
|   Site Map   |
Useful Links
GenTech Scientific, Inc.
23 Mill Street Arcade, NY 14009
Phone: (585) 492-1068
Fax: (585) 492-0383
E-Mail:
sales@GenTechScientific.com

© 2005 GenTech Scientific, Inc.
All prices subject to change without prior notice. Please send comments or questions to the
Webmaster.